When using the redfish LogServices/Event uri (“/redfish/v1/Systems/1/LogServices/Event/Entries?$expand=.”) to read the event entries, if the event has a "MessageId": "iLOResourceEvents.1.4.AggregateHealthStatusChange", fields are missing. There should be fifteen fields based on:https://servermanagementportal.ext.hpe.com/docs/redfishservices/ilos/ilo6/ilo6_170/ilo6_msgregs170#iloresourceevents.1.4.aggregatehealthstatuschangeHowever, depending on the server, there could be ten-thirteen arguments. The missing fields vary from server to server; hence, this record is useless.Example:"EventTimestamp": "2025-10-11T12:51:24Z","Links": {"OriginOfCondition": {"@odata.id": "/redfish/v1/Systems/1"… Example of a 13 argument, when there should be 15, the results are missing 2 fields."Message": "AggregateServerHealth is %1,...."MessageArgs": ["OK","OK","Redundant","OK","OK","Unknown","OK","False","Redundant","OK","OK","OK","OK"],"MessageId": "iLOResourceEvents.1.4.AggregateHealthStatusChange","Name": "Event","OemRecordFormat": "Hpe-Event","Severity": "OK"When any Health Status value is unavailable, the records stored in the alert database will omit that field. In the above case, this server does not have any Liquid cooling; therefore, those fields have been dropped, shifting everything up by two. Instead, it should be as follows:"MessageArgs": [ if all 15 fields are there"OK","OK","Redundant","OK","", <<<< LiquidCoolingRedundancy is blank"",<<< LiquidCooling is blank"OK", << now everything is in line"OK","OK","False","Redundant","OK","OK","OK","OK"],It should be noted that missing fields will vary depending on which values are available. During boot, the message may be missing anywhere between two and seven values.
Any HPE system with iLO.
To resolve this issue, update to iLO 7 firmware v1.23 (or later) or iLO 6 firmware v1.73 (or later).To download iLO 7 v1.60 (or later) or iLO 6 v1.73 (or later), perform the following steps:Click the following link:http://www.hpe.com/support/ilo7orhttp://www.hpe.com/support/ilo6The page should refresh to display the "DRIVERS AND SOFTWARE" tab and the components that support the selected product. From the "DRIVERS AND SOFTWARE" expandable filter menus on the left side of the page:For further filtering if needed - Select the specific Operating System from the Operating Environment.Locate and select theHPE Integrated Lights-Out 7 v1.60 firmwareorHPE Integrated Lights-Out 6 v1.73 firmware.click the Revision History tab to locate the latest version.For more important information, review the Release Notes tab.Click theDownloadbutton.Document VersionRelease DateDetails2August 6, 2026Added fix, iLO 7 firmware v1.23 and iLO 6 firmware v1.73.1November 18, 2025Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.