For any HPE Synergy 480 Gen12 Compute Modules, in rare instances, the server may fail to boot into the OS after applying a Server Profile via OneView.This issue may occur when the Security Protocol and Data Model (SPDM) Global Component Integrity Policy on HPE Integrated Lights-Out (iLO) is configured to "Halt boot on SPDM Failure", as shown below.Global Component Integrity: EnabledComponent Integrity Policy: Halt boot on SPDM FailureWhen this issue occurs, the Integrated Remote Console (IRC) will display the following messages:"Halted system because time out exceeded out after 1 seconds..."Additionally, the Integrated Management Log (IML) will report the following error:"Component Integrity Failure. Unable to obtain Component Integrity from iLO. System Halted!"
In the scenario described above, any OneView version managing HPE Synergy 480 Gen12 Compute Modules.
If this issue has already occurred, reboot the affected compute module to restore normal operation.