HPE Compute Scale-up Server 3200 server may boot with multiple CPU cores de-configured after the complex firmware is updated to version 1.60.88. Due to a timing issue, during boot, the processors are unable to complete certain boot time procedures, causing AP_CPU_REDEZVOUS_FAIL events and eventually disable cores. As it is timing related, this occurs random/intermittent.A common error signature when this problem occurs isIntegrated Event Log (IEL):-----505881 2025-10-06 10:36:32Z SFW r001u01p0c00t0 0 *WARN (3) 0001000101000006 AP_CPU_RENDEZVOUS_FAIL [rack1/chassis_u1/cpu0/core1/thread0]505882 2025-10-06 10:36:32Z SFW r001u01p0c00t0 0 *WARN (3) 0005000101000006 AP_CPU_RENDEZVOUS_FAIL [rack1/chassis_u1/cpu0/core5/thread0]505883 2025-10-06 10:36:32Z SFW r001u01p0c00t0 0 *WARN (3) 000F000101000006 AP_CPU_RENDEZVOUS_FAIL [rack1/chassis_u1/cpu0/core15/thread0]505884 2025-10-06 10:36:32Z SFW r001u01p0c00t0 0 *WARN (3) 0017100101000006 AP_CPU_RENDEZVOUS_FAIL [rack1/chassis_u1/cpu0/core23/thread1]505885 2025-10-06 10:36:32Z SFW r001u01p0c00t0 0 *WARN (3) 0019000101000006 AP_CPU_RENDEZVOUS_FAIL [rack1/chassis_u1/cpu0/core25/thread0]Core Analysis Engine (CAE):-----RMC cli> show cae listIndex Date Time Id Category Par# Severity Summary Physical Location===== ========== ========= ==== =============== ==== ========310 2025-10-06 10:39:34Z 569 Processor 0 Fatal A core reported in as defective and was indicted rack1/chassis_u1/cpu3/core59309 2025-10-06 10:39:34Z 569 Processor 0 Fatal A core reported in as defective and was indicted rack1/chassis_u1/cpu3/core59308 2025-10-06 10:39:33Z 569 Processor 0 Fatal A core reported in as defective and was indicted rack1/chassis_u1/cpu3/core57307 2025-10-06 10:39:33Z 569 Processor 0 Fatal A core reported in as defective and was indicted rack1/chassis_u1/cpu3/core58306 2025-10-06 10:39:33Z 569 Processor 0 Fatal A core reported in as defective and was indicted rack1/chassis_u1/cpu3/core58
Any HPE Compute Scale-Up Server 3200 systems running complex firmware version 1.60.88.
To resolve this issue, update toHPE Compute Scale-up Server 3200 Firmware Bundle version 1.65.60(or later).HPE Compute Scale-up Server 3200 Firmware Bundle version 1.65.60 is a critical release and HPE strongly recommends customers to update their systems to this version at the earliest.If updating to 1.65.60 is not an option, acquitting the de-configured cores, then disabling Hyper Threading and rebooting the system can be used as a workaround.To disable Hyper Threading, refer to theHPE Compute Scale-up Server 3200 Configuration Guide
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.