Primary DP2 CPU might halt with halt code %5100, when one half of the mirrored volume becomes inaccessible. Though this defect existed since DP2 SPR T9053L03^BBR (L18.08 RVU), the probability of its occurrence increases with the installation of DP2 SPR T9053L03^BDB or its superseding SPRs. This Hotstuff details the conditions under which this problem occurs and the DP2 version that corrects this problem.A Primary DP2 CPU might halt with halt code %5100 when one half of the mirrored volume becomes inaccessible. This is a timing related issue between two DP2 PINs of the same volume and can occur when one of the Primary/Mirror disk pair for the volume becomes inaccessible while I/Os are in progress.When one half of a mirrored DP2 volume becomes inaccessible, one of the DP2 PINs detects this event and tries to set up the Revive environment. If another DP2 PIN which is performing a regular I/O tries to access this Revive environment before the first DP2 PIN completes its setup, it can lead to an internal inconsistency. This inconsistency causes a %5100 halt in the Primary DP2 CPU.Though this defect existed since DP2 version T9053L03^BBR (L18.08 RVU), the probability of its occurrence has increased since the DP2 version T9053L03^BDB. A code change in T9053L03^BDB increases the concurrency between the DP2 PINs and that in turn increases the chances of encountering this timing issue.Likelihood:Very unlikely - if DP2 version is older than T9053L03^BDB.Somewhat likely - if DP2 version is T9053L03^BDB or later.
Affected Software Product Revision(s) (SPR(s)):T9053L03^BBZ T9053L03^BCE T9053L03^BCH T9053L03^BCJ T9053L03^BCK T9053L03^BCM T9053L03^BCO T9053L03^BCQ T9053L03^BCS T9053L03^BCT T9053L03^BCU T9053L03^BCW T9053L03^BCX T9053L03^BCZ T9053L03^BDA T9053L03^BDB T9053L03^BDC T9053L03^BDD T9053L03^BDE T9053L03^BDFRelease Version Updates (RVUs) containing the affected SPR(s):L18.08.00 - L23.08.02Additional RVUs potentially affected because one or more of the SPRs listed above is usable with them:L17.08L17.08.01
RVUs containing final fix:L23.08.03 - already availableL24.08 - already availableNo fix is planned for the following RVUs:L17.08 - L20.10PREVENTIVE ACTION:Workaround: NoneFix:Install T9053L03^BDI ( DP2 ) or a superseding SPR.One of these SPRs already is present in these RVUs:L23.08.03L24.08.00 - OnwardsThese SPRs are also usable with the following RVUs:L21.06 - L23.08.02Installation impact: SYSGEN and system load required. You can check with the GNSC for applicability of the above SPR to RVURs that have been released since the publication of this Hotstuff.Please refer to T9053L03^BDI softdoc for detailed SPR information, including installation instructions, superseded SPRs, and requisite SPR lists.Note: In some cases, requisite SPRs might have greater installation impact than the SPR(s) described in this Hotstuff.
Operating Systems Affected:NonStop OS L15.02-L23.08, NonStop OS L24.08, NonStop OS L25.02, Nonstop OS L25.09
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.