Loading...
Loading...
Any HPE Gen12 server with HPE Integrated Lights-Out 7 (iLO 7) and directly connected NVMe SSDs may take relatively more time to perform an update and may result in an error due to a timeout. As a result, a few of the NVMe drives may contain older firmware versions than other drives.When the issue occurs, a message similar to the following example will be reported in the iLO Event Log:"Firmware Update Error - Box <box>, Bay <bay> - NVMe firmware was not updated."
Any HPE Gen12 servers running HPE Integrated Lights-Out 7 with any compatible and NVMe directly attached Solid State Drives (SSDs).
HPE recommends a retry with the same specific package to update the drive firmware. This time it should be successful.This issue is resolved in HPE Integrated Lights-Out 7 (iLO 7) Firmware Version 1.18. The firmware can be updated by using theOnline ROM Flash Firmware Package - HPE Integrated Lights-Out 7.
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration