The management network of a Virtual Machine (VM2) cloned from an existing Virtual Machine (VM1) may become unreachable when this new cloned Virtual Machine (VM2) is powered on for the first time.This occurs when a vSAN ESA cluster using VMware Cloud Foundation (VCF) 9.0 via Software-Defined Data Center (SDDC) Manager is deployed on any HPE Synergy 480 Gen11 Compute Module or HPE Synergy 480 Gen12 Compute Module running VMware ESXi 9.0, and configured with an HPE Synergy 6310C 25/50Gb Ethernet Adapter (P64724-B21), and the whole VMware Cloud Foundation (VCF) deployment is setup successfully.The first Virtual Machine (VM1) created in the management or worker domain gets the Dynamic Host Configuration Protocol (DHCP) IP address successfully; but once other Virtual (VM2) is cloned from the first Virtual Machine (VM1), the management network of the Virtual Machine (VM2) may become unreachable when this Virtual Machine is powered on for the first time.
Any HPE Synergy 480 Gen11 Compute Module or HPE Synergy 480 Gen12 Compute Module running VMware ESXi 9.0, and configured with an HPE Synergy 6310C 25/50Gb Ethernet Adapter (P64724-B21) with Virtual Machines created on a vSAN ESA cluster using VMware Cloud Foundation (VCF) 9.0 via Software-Defined Data Center (SDDC) Manager.
To resolve this issue, download and install firmware combo version 234.1.146000 available in the following firmware component:HPE Synergy Firmware for Broadcom NetXtreme-E Devices Version 234.1.146000WorkaroundTo temporarily resolve this issue, perform either of the following actions:Reboot the virtual machineORManually re-create the VMware vSphere Distributed Switch (VDS) and the Port Group (PG) on vCenter with the same VLAN as the management network.Disclaimer:One or more of the links above will take you outside the HPE website. HPE is not responsible for content outside of its domain.Revision HistoryDocument VersionRelease DateDetails2October 7, 2025A final fix has been added to the Resolution section.1July 22, 2025Original Document Release.
Operating Systems Affected:VMware ESXi 9.0
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.