For any HPE Synergy compute modules with an HPE Synergy 6310C 25/50Gb Ethernet Adapter, and a OneView Server Profile configured with connection subports "a" through "h", if any of the connection subports "a" through "g" are unassigned or are not created in the Server Profile, the subport "h" will show as disconnected and OneView will show a message similar to the following:"The connection on downlink port <port#>, subport h has failed. The subport is unlinked."When the above message is displayed, the network connectivity will not be affected, and the Operating System will show a link UP. The subport "h" will remain connected to the assigned network.
In the scenario described above, the following Compute Modules configured with an 6310C Ethernet adapter:HPE Synergy 480 Gen11 Compute ModuleHPE Synergy 480 Gen12 Compute Module
The error message from OneView does not affect the system functionality and can be safely ignored.A future adapter firmware will avoid this issue. This advisory will be updated when additional solutions become available.As a workaround, perform either of the following:If subport "h" (Port 3:1-h) is configured, ensure that all other connection subports (Port 3:1-a to 3:1-g) are configured and have an assigned network.ORIf not needed, delete the subport "h" connection in the Server Profile.