On the following HPE MR controllers and their firmware, the RAID1/5/6/10/50/60 array rebuild will not automatically start after a failed drive is replaced with a drive that was previously configured as JBOD on the same controller:HPE Smart Array P824i-p MR Gen10 controller with firmware version 24.23.0-0048HPE MR Gen10+ and Gen11 controllers with firmware version 52.22.3-4650 or earlierThe new drive will appear as a JBOD:In addition, the array will be "Degraded", and the disk will appear asMissing:
This advisory applies to the following controllers and firmware versions:HPE Smart Array MR Gen10 controllersHPE Smart Array P824i-p MR Gen10 12G SAS PCIe Controller running firmware version 24.23.0-0048 (870658-B21)HPE MR Gen10 Plus and Gen11 controllers running firmware version 52.22.3-4650 and earlierHPE MR408i-o Gen11 x8 Lanes 4GB Cache OCP SPDM Storage Controller (P58335-B21)HPE MR416i-o Gen11 x16 Lanes 8GB Cache OCP SPDM Storage Controller (P47781-B21)HPE MR216i-o Gen11 x16 Lanes without Cache OCP SPDM Storage Controller (P47789-B21)HPE MR408i-p Gen11 x8 Lanes 4GB Cache PCI SPDM Plug-in Storage Controller (P74775-B21)HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller (P47777-B21)HPE MR216i-p Gen11 x16 Lanes without Cache PCI SPDM Plug-in Storage Controller (P47785-B21)HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P26279-B21)HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P06367-B21)HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26325-B21)HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26324-B21)
To prevent this issue, upgrade the HPE MR Gen10 Plus and Gen11 controllers to firmware version 52.24.3-4948 or later, and upgrade the HPE Smart Array P824i-p MR Gen10 controller to firmware version 24.23.0-0049 or later using the following links:HPE Smart Array P824i-p ControllerHPE MR Gen10 Plus ControllersHPE MR Gen11 ControllersIf the issue already occurred, then perform actions in the following order in the "Elements(s) Actions" section, on the right side of the HPE MR Storage Administrator (MRSA) window, to manually start the array rebuild on the replacement drive.In theDrives > JBODsection, select the replacement drive and clickMake Unconfigured Good. The replacement drive is now changed to "Unconfigured Good".In theDrives > Unconfigured Good Drivessection, select the replacement drive and clickAssign Dedicated Spare.The Arrays dialog will display. Select the degraded array to assign the Dedicated Spare.The replacement drive is now changed to "Configured, status Rebuild".Once the rebuild is complete, the disk will appear asOnlineand the array as optimal.Revision HistoryDocument VersionRelease DateDetails2August 14, 2025Content updated in the Title, affected products, and all sections of the document to include Gen10 Plus and Gen11 controllers, and corrected steps in the Resolution section1January 10, 2024Original Document Release
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.