The Mellanox Ethernet+RoCE driver will not load on HPE systems running SUSE Linux Enterprise Server 15 Service Pack 4 installed with Errata Kernel 5.14.21-150400.24.11.1 (or later). One or more symbols that the Mellanox driver modules used were altered with the errata kernel version 5.14.21-150400.24.11.1; therefore, breaking the kABI for the driver modules. After restarting the driver modules, an Out of Memory issue occurs, causing the system to stop responding and display the following message:
Any HPE system configured as follows: The following driver versions are affected: Mellanox Ethernet+RoCE driver version 5.8. The following Operating System/kernel versions are affected: SuSE Linux Enterprise Server 15 Service Pack 4 installed with Errata Kernel 5.14.21-150400.24.11.1 and future updates. The following Adapters are affected: HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21) HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21) HPE Ethernet 100Gb 1-port QSFP28 MCX515A-CCAT Adapter (874253-B21) HPE Ethernet 10/25Gb 2-port SFP28 MCX4121A-ACUT Adapter (817753-B21) HPE Ethernet 10/25Gb 2-port FLR-SFP28 MCX4121A-ACFT Adapter (817749-B21) Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21) Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21) HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21) HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21) HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21) HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21) HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21) HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 /872726-H21) HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21 / 872725-H21) HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 /825111-H21) HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 /825110-H21) Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21) Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21) Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21) Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21) HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter(P23665-B21 / P23665-H21) HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter(P23664-B21 / P23664-H21) HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter(P06154-B21 / P06154-H21) HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21) HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21 / P06251-H21) HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21) HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21) HPE Synergy 6410C 25/50Gb Ethernet Adapter (868779-B21) HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/P06250-H21)
Cold reboot the system if an Out of Memory issue occurs after the driver modules are loaded. After the OS boots back up and the console is available, use the following command to uninstall the RoCE driver RPMs: ofed_uninstall.sh After the driver RPMs are uninstalled, install the new driver RPMs built on errata kernel version 5.14.21-150400.24.11.1: For the Synergy Network Adapter HPE Synergy 6410C 25/50Gb Ethernet Adapter(868779-B21), use: MellanoxEthernet+RoCE driver version 5.8-1.1.2.1(A) compiled for errata kernel For other affected Network Adapters, use: MellanoxEthernet+RoCE driver version 5.8(A) compiled for errata kernel RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL: HPE Email Preference Center NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to the Navigation Tips document. SEARCH TIP: For hints on locating similar documents on HPE.com, refer to the Search Tips document.
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.