It was observed after hundreds of iterations of an AC power cycle test, Intelligent Platform Management Interface (IPMI) commands stopped working to the HPE Integrated Lights-Out 5 (iLO 5).The continuous AC power-cycle may cause the NVRAM content of the IPMI configuration to enter a transient state and lose integrity when the power is removed abruptly. When iLO 5 power is restored, the IPMI configuration file is checked and is re-initialized to default values as a self-recovery operation.Note: For security, the factory default setting for the IPMI-Over-Lan is always disabled.This has been observed with iLO 5 firmware v2.63. This has not been observed with iLO 5 firmware later than v2.63.
Any HPE system with iLO 5 firmware v2.63.
This issue is resolved in HPE Integrated Lights-Out 5 (iLO 5) v2.72 (or later).Workaround:If this has occurred, go to the Network section on the Access Settings page and re-enable IPMI access.In addition, use the iLO 5 Backup & Restore functionality for the iLO 5 configuration settings to recover from this issue.Any of the options below are available for an iLO 5 Backup & Restore:Using iLO 5 web interface: click the navigation tree and then click Backup & Restore.Using iLO Redfish API as follows:GET /redfish/v1/managers/1/backuprestoreserviceGET the backup file based upon the "BackupFileLocation" URIThe GET operation to the BackupFileLocation URI returns HTTP 200 with Content Type: application/octet-stream. This is the binary image of the backup file.For additional details on the procedure and pre-requisites, refer to the “iLO backup and restore” section of theiLO 5 User Guide.A future iLO 5 firmware version is targeted to automatically back up settings and restore on initialization when a change is detected. This advisory will be updated when additional information is available.Revision HistoryDocument VersionRelease DateDetails2November 14, 2024The Resolution was updated with the version of iLO 5 that resolves this issue.1July 5, 2022Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.