HPE Intelligent Provisioning Versions 2.40, 2.40(B), or 2.50 on Gen9 systems or IP 3.20 on Gen10 systems may set the partition attributes of the Recovery Partition to 0xC0000000000000001 instead of 0x80000000000000001 during installation of the Intelligent Provisioning media.
In most instances, this does not cause any issues; however, when this happens, backup applications may not back up the volume as expected.
Scope
Any ProLiant Gen9 server using HPE Intelligent Provisioning Version 2.40, 2.40 (B), or 2.50, or ProLiant Gen10 server running IP 3.20 (or earlier).
Resolution
For Gen10 and Gen10 Plus servers, Intelligent Provisioning 3.50 will change this attribute.
For Gen 9 systems, correct the attributes using Diskpart as follows:
DISKPART>GPT attributes=0x8000000000000001
This advisory will be updated if additional solutions become available.
RECEIVE PROACTIVE UPDATES
: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:
Proactive Updates Subscription Form.
NAVIGATION TIP
: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the
Navigation Tips document
.
SEARCH TIP
: For hints on locating similar documents on HPE.com, refer to the
Search Tips document
.