Applies to: - All Data Domain systems Possible Symptoms: BMC becomes unresponsive. iDRAC is offline or unreachable. False or transient alerts related to: Fans Power supplies Temperature sensors Multiple head unit sensors report as "Unavailable" , "Absent" , or "Failed" . Posted alert EVT-ENVIRONMENT-00039: BMC failure has been detected. File system is unchanged.
The BMC or iDRAC may stop responding due to internal faults or excessive traffic, resulting in stale or erroneous alerts. A reset clears these conditions and restores sensor functionality.
All DD systems BMC/iDRAC reset procedure: Power off the Data Domain system by issuing the DD-CLI Command: #system poweroff Wait for the DD system to gracefully shut down. Remove all AC Power cables from DD Head unit/Controller. Wait for 2 minutes. Plug all the power supplies back in and boot the system by pressing the power button on the front panel. If the system is still experiencing BMC issues, contact your support provider. NOTE: Dell PowerEdge 'Flea Drain' procedure: Data Domain: DD3300/DD6900/ DD9400/DD9900 Platform Flea Drain (BMC Reset) Procedure . Alternative 'Soft Reset' option for PowerProtect DD Systems: The Graphical User Interface (user interface) of the iDRAC provides an option to perform a soft reset: Connect to iDRAC. Log in to the interface by entering the username and password. Select: Maintenance > Diagnostics > Reset iDRAC The iDRAC is not reachable for few minutes - system performance is not affected. Attention: Do not select "Reset iDRAC to Default Settings" unless you intend to restore all settings (including IP, username, and password) to factory defaults.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.