VMware Cloud Foundation (VCF) on VxRail upgrade fails on the pre-check steps for NSX-T Edge Nodes Error message listed in SDDC Manager GUI states: NSX-T upgrade failed in precheck for edge clusters. Check for errors in the LCM log files at 127.0.0.1:/var/log/vmware/vcf/lcm, and address those errors. Restart the upgrade Error message listed in NSX-T Manager GUI under 'Edges' section states: Edge transport node status information not found from MP data for edge node <UUID> when selecting System > Upgrade > Upgrade Summary > Pre Check Status SDDC Manager GUI:
The 'admin' user on NSX-T Edge nodes has an expired password. This can be confirmed by opening an SSH session and logging in to the Edge nodes.
Update the expired password on the NSX-T Edge nodes. After updating, set the password back to the original value via the " set user admin " command. Optionally, the password expiration policy can be adjusted afterwards. More information regarding password management can be found in the below document. https://docs.vmware.com/en/VMware-NSX-T-Data-Center/2.4/administration/GUID-DB31B304-66A5-4516-9E55-2712D12B4F27.html