When the save set is not from a Block Based Backup (BBB) the save set recover command will disregard the -I - switch and will begin recovering data.Here is an example of the output C:\Users\Administrator>recover -vvv -d C:\Test -S 4271161932 -I -Recovering a subset of 6 files within C:\ into C:\TestRecover start time: 8/16/2017 3:11:34 PMRequesting 1 recover session(s) from server.recovering 6 save set(s) on rsid 376508/16/17 15:12:32.804977 libDDBoost version: major: 3, minor: 0, patch: 3, engineering: 0, build: 499747C:\Test\<directory>\2016.07.21-notes.txt -rC:\Test\<directory>\recover\ -rC:\Test\<directory>\tinesgl1_jobsdb.sql -rC:\Test\<directory>\ -r time = 4277847 microseconds, <0:00:04.277847>Received 4 matching file(s) from NSR server `rastaman'Recover completion time: 8/16/2017 3:12:38 PMC:\Users\Administrator>
The syntax of the command line recover is applicable to BBB backups.
Ensure the save set that is chosen for the recover is from a BBB backup. To verify, use the mminfo command mminfo -a -S -q ssid=<ssid> The output will have "*BlockBasedBackup: Yes" if it is. To "search" for BBB backups, as Doumented in the NetWorker 9 Administration Guide a new mminfo query ssattr is introduced mminfo -avot -q "ssattr=*BlockBasedBackup" NetWorker 8 will take a bit of scripting in PowerShell for Windows or with Unix/Linux. for a start PS C:\Users\Administrator> mminfo -avot -S | select-string -context 10, 0 -pattern BlockBasedBackup > foo.txtPS C:\Users\Administrator> select-string -pattern "ssid=" foo.txt | %{ $_ -split(' ')[0]; } | select-string -pattern "ssid="ssid=4287841403ssid=4271064190ssid=4254300420PS C:\Users\Administrator>
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.