All the paths are place in asb:prox for a non-distributed volume. eg:- Pseudo name=emcpower8 VPLEX ID=CKM00AAAAAAAA Logical device ID=xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Standard UID=naa.xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx type=Conventional; state=alive; policy=ADaptive; queued-IOs=0 ====================================================== --------------- Host --------------- - Stor - -- I/O Path -- -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ====================================================== 3 vmhba1 C0:T0:L14 CL2-00 asb:prox alive 0 1 2 vmhba2 C0:T1:L14 CL2-03 asb:prox alive 0 0 3 vmhba1 C0:T2:L14 CL2-01 asb:prox alive 0 0 2 vmhba2 C0:T3:L14 CL2-02 asb:prox alive 0 1 Pseudo name=emcpower0 VPLEX ID=CKM00AAAAAAAA , CKM00BBBBBBBB Logical device ID=yyyyyyyyyyyyyyyyyyyyyyyyyyyyy Standard UID=naa.yyyyyyyyyyyyyyyyyyyyyyyyyyyyy type=Conventional; state=alive; policy=ADaptive; queued-IOs=0 ====================================================== --------------- Host --------------- - Stor - -- I/O Path -- -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ====================================================== 1 vmhba4 C0:T2:L0 CL2-03 asb:prox alive 0 0 1 vmhba4 C0:T3:L0 CL2-02 asb:prox alive 0 1 4 vmhba3 C0:T2:L0 CL2-01 asb:prox alive 0 0 4 vmhba3 C0:T1:L0 CL2-00 asb:prox alive 0 1 1 vmhba4 C0:T1:L0 CL1-03 active alive 0 0 4 vmhba3 C0:T3:L0 CL1-00 active alive 0 0 4 vmhba3 C0:T0:L0 CL1-01 active alive 0 0 1 vmhba4 C0:T0:L0 CL1-02 active alive 0 0
PowerPath detects the most optimal paths (local paths) and places the remote paths in autostandby mode. In mixed environments (VPLEX clusters with paths configured to cross-connected distributed volumes as well as paths configured to non-distributed volumes), the paths to the non-distributed volume inherit the cluster mode allocation that the proximity algorithm applies to its VPLEX cluster. For example, the PowerPath proximity algorithm designates a VPLEX cluster as local and preferred for a crossconnected, distributed volume on the host. After the distributed volume is designated as local, all paths to that cluster will be set as active. In addition, even if there is a non-distributed volume in the cluster, paths to that non-distributed volume are also set as active. This setting is inherited from the global setting set on the VPLEX cluster. In some scenario all paths to a volume are in asb:prox, then PowerPath/VE selects paths for I/O as if all paths are active.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.