Consistency Groups are in an Error state or paused by system, init , and error loops. Sample state from the get_group_state command: CG: Enabled: YES Transfer source: Source Copy: Target: Enabled: YES Regulation Status: REGULATED Active primary RPA: RPA 1 Journal: LONG RESYNC Storage access: NO ACCESS Max journal size: 1.09 TB Source: Enabled: YES Active primary RPA: RPA 1 Storage access: DIRECT ACCESS (marking data) Link: Source->Target: Data Transfer: ERROR Events in the UI or CLI get_events_log : Time: Mon Jan 16 15:29:30 2017 Topic: GROUP Scope: DETAILED Level: ERROR Event ID: 4009 Cluster: Target_Site_vRPA Global links: None Groups: [CG, CG_Copy] Links: [CG, CG_Prod->CG_Copy] Summary: Pausing data transfer for group Details: Reason= distributor error . Time: Mon Jan 16 15:31:03 2017 Topic: GROUP Scope: DETAILED Level: WARNING Event ID: 4001 Cluster: Source_Site Global links: None Groups: [CG, CG_Prod] Summary: Minor problem in group capabilities Details: Copies are linked.RPA1: Marking (GlobalCopy(SiteUID(0x1207d88a9b552bf9) 0) ) = Yes - side defined as source. Site=Source_Site. Source backlog mirroring (GlobalCopy(SiteUID(0x1207d88a9b552bf9) 0) ) = NOT NEEDED Transfer (GlobalCopy(SiteUID(0x7b8822840a7e317f) 0) ) = NO - can't maintain history - not paused on snapshot and user volume problem - Volume issue. Site=Target_Site, RPA1, Device=[CG, CG_Copy, CG_RSET_CG_3_0_scsi]. Box and VM share ESX = SAME_ESX_NOT_SAMERPA2: Marking (GlobalCopy(SiteUID(0x1207d88a9b552bf9) 0) ) = Yes - side defined as source. Site=Source_Site. Source backlog mirroring (GlobalCopy(SiteUID(0x1207d88a9b552bf9) 0) ) = NOT NEEDED Transfer (GlobalCopy(SiteUID(0x7b8822840a7e317f) 0) ) = Yes Journal (GlobalCopy(SiteUID(0x7b8822840a7e317f) 0) ) = Yes Target backlog mirroring (GlobalCopy(SiteUID(0x7b8822840a7e317f) 0) ) = NOT NEEDED Preferred = NO Box and VM share ESX = SAME_ESX_SAME Number of VMs in same ESX is 1 Error in replication logs ( extracted.*/files/home/kos/replication/result.log ): 2017/01/16 13:03:30.187 - #1 - 5508/5482 - DataCommIoRequest: Got NACK from splitter, Error code = 2 *m_kboxDataCommMessage = KboxDataCommMessage, DataCommMessage, m_multiIoId: 1804479667 m_msgId: 17968710 m_type: 1 m_lbaAndLens: 1 lengthInBlocks: 1024 m_guid: 0x69f6a49648317aec m_version: 0 m_isFastPath: 1 m_hostId: ESX 0x10f9536584e11e30 m_priority: 6 Errors in splitter logs in host seen in replication logs above ( m_hostId: ESXi 0x10f9536584e11e30 ): 2017/01/16 13:11:13.714 - #2 - 570188/570154 - KS: krnl:[13:11:13.594] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: IO 0x41132aa45240 Failed. Host_Status = 0x0, Device_Status = 0x8, dataLength = 393216 krnl:[13:11:13.594] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: numFSSRetries = 0, numFDSRetries = 0, absTimeoutMS = 250463060, startTC = 0 krnl:[13:11:13.594] 0/0 #0 - CommandIoDataCommWrite_v_storageEndIo_i: Failed write to storage. io_index = 0. Io status 0. Failing DataComm Write. 2017/01/16 13:11:14.828 - #2 - 570188/570154 - KS: krnl:[13:11:14.289] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: IO 0x41132aa41210 Failed. Host_Status = 0x0, Device_Status = 0x8, dataLength = 393216 krnl:[13:11:14.289] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: numFSSRetries = 0, numFDSRetries = 0, absTimeoutMS = 250463777, startTC = 0 krnl:[13:11:14.289] 0/0 #0 - CommandIoDataCommWrite_v_storageEndIo_i: Failed write to storage. io_index = 0. Io status 0. Failing DataComm Write. 2017/01/16 13:11:15.937 - #2 - 570188/570154 - KS: krnl:[13:11:15.118] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: IO 0x41132aa44c90 Failed. Host_Status = 0x0, Device_Status = 0x8, dataLength = 393216 krnl:[13:11:15.118] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: numFSSRetries = 0, numFDSRetries = 0, absTimeoutMS = 250464606, startTC = 0 krnl:[13:11:15.118] 0/0 #0 - CommandIoDataCommWrite_v_storageEndIo_i: Failed write to storage. io_index = 0. Io status 0. Failing DataComm Write. krnl:[13:11:15.676] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: IO 0x4113298f6108 Failed. Host_Status = 0x0, Device_Status = 0x8, dataLength = 393216 krnl:[13:11:15.676] 0/0 #0 - IoEsx_ToStorage_v_isSucceeded_i: numFSSRetries = 0, numFDSRetries = 0, absTimeoutMS = 250465165, startTC = 0 krnl:[13:11:15.676] 0/0 #0 - CommandIoDataCommWrite_v_storageEndIo_i: Failed write to storage. io_index = 0. Io status 0. Failing DataComm Write.
The Data Store on the target side for these Consistency Groups had no free space, so RecoverPoint could not write to them.
Review the target side ESXi to see that all target Data Stores (for target hosts and journals) have free space. For Data Stores without space, free up space or increase the Data Store size, so RecoverPoint can write to it.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.