New installation. New Sybase clients are not able to be configured via the Networker Management wizard. All credentials are fine. All Sybase Information are correct, but Networker display error: "Sybase server connection failed. Check username, password, server name, Sybase installation directory and Sybase server"
Missing networker startup script /nsr/nsrrc or if present, all lines in /nsr/nsrrc are commented
==> If the script is present and have all line commented just un-comment and/or add the lines: # Setting open file limit and max process ulimit -n 65535 ulimit -u 65535 LANG=en_US.UTF-8 export LANG ==> If not present, create a new one with the lines as: Add to networker startup script in /nsr/nsrrc #!/bin/sh # # Called via Networker startup script # # Source Bourne shell scripts to set the environment variables # # Setting open file limit and max process ulimit -n 65535 ulimit -u 65535 LANG=en_US.UTF-8 export LANG