Loading...
Failed to manage the SP from the ControlStation: [nasadmin@CS0~]$ /nas/sbin/navicli -h spa getagent Error returned from the Management Server on xx.xx.xx.xx Authentication failed. Possible reason for failure is excessive failed authentication attempts. Restarting the management server on the SP did not resolve the problem. Updating the correct SP credential on the ControlStation did not resolve the problem.
An incorrect credential was configured on another host that was trying to access the SP. The error messages on the SP are as follows: B 11/17/16 15:29:34 4640 Access is denied called by 'srmuser'. Application Accessed: ManagementServer. Result: Failure. B 11/17/16 15:29:34 4640 Access is denied called by 'srmuser'. Application Accessed: ManagementServer. Result: Failure. B 11/17/16 15:29:34 4640 Access is denied called by 'srmuser'. Application Accessed: ManagementServer. Result: Failure. The SP blocked access from all hosts because of the excessive requests from this host.
Identify the host that has the incorrect credential configured, and correct it. The Username and IP address can be found in the SP log.