Replication stops after Data Mover server_2 fails over to server_3 with the following error: Warning 17455382845: Network communication has been lost Interconnect validation fails: nas_cel -interconnect -validate Replication_DR Error 12202: Interconnect validate failed between source interface and destination inestination interface=10.1.XX.46, Message_ID=13160415819: Unable to connect to destination The source interface can ping the destination interface. The DR is unable to ping the source, but the default gateway is pingable: server_ping server_2 10.1.XX.46 server_2 : Error 6: server_2 : No such device or address no answer from 10.1.XX.46server_route server_2 -list server_2 : default 10.1.XX.1 0.0.0.0 Replication_DR net 128.XXX.253.0 128.XXX.253.2 255.XXX.255.0 el31 net 128.XXX.252.0 128.XXX.252.2 255.XXX.255.0 el30 net 10.1.XX.0 10.1.XX.15 255.XXX.255.0 Replication_DR net 10.0.0.0 10.1.XX.23 255.0.0.0 FILE-SRV04_INT host 127.X.X.1 127.X.X.1 255.XXX.255.255 loopserver_ping server_2 10.1.XX.1 server_2 : 10.1.XX.1 is alive, time= 0 msnas_cel -interconnect -info -all --> from Secondary siteid = 20003 name = Replication_DR source_server = server_2 source_interfaces = 10.1.XX.15 destination_system = JO00-VNX5400-CS0 destination_server = server_2 destination_interfaces = 10.1.XX.46 bandwidth schedule = uses available bandwidth crc enabled = yes number of configured replications = 28 number of replications in transfer = 0 status = The interconnect is OK.
The default gateway of the secondary array is unable to reach the source interface after the Data Mover has failed over or rebooted.
Add a static route for the DR interface to reach the primary: server_route server_2 -add host <dest> <gateway> server_route server_2 -add host 10.1.XX.46 XX.1.XX.1 server_2 : done Ping the primary to test the connection: server_ping server_2 10.1.XX.46 server_2 : 10.1.XX.46 is alive, time= 0 ms Validate the interconnect: nas_cel -interconnect -validate Replication_DR Replication_DR: has 1 source and 1 destination interface(s); validating - please wait...ok
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.