CE replaced DIMMs on the data mover and the "setup_slot -init" command failed with the above nas_checkup errors. Blades : Check unique id Error HC_DM_14505148498: * The uniqueid reported by the Blade server_3 does not match the /nas/server/slot_3/start file. Action : Escalate this issue through your support organization if needed. Provide this output in the escalation. Blades : Check slic signature Error HC_DM_14505148557: No SLIC signature in device file. grep slicsignature /nas/server/slot_3/device command failed with exit code 1. Action : Investigate by running the command manually. Escalate this issue through your support organization if needed and refer to EMC Knowledgebase number emc195492. Provide this output and the output from any commands that you ran for this procedure in the escalation.
slicsignature validate ID is missing from /nas/server/slot_x/deviceuniqueid validate ID is missing from /nas/server/slot_x/start [nasadmin@xxxxx ~]$ cat /nas/server/slot_3/device device isa isa-0 device pci pci-0 dskdumpconfig full slot=3 pciautoconfig el3config tier2-aui slicsignature validate=132613 [nasadmin@ xxxxx ~]$ cat /nas/server/slot_3/start -serial swapserial #verify_start flashupg post=upgrade bios=upgrade fwbd=upgrade logsys add output disk=root_log_3 bufsz=256 logsys add output event bufsz=2048 ap boot setid celerraid=APXXXXXXXXXXXXXXXX setinitiator cs_hostname=Celerra_ xxxxx cs_external_ip=10.241.183.190 uniqueid validate=50060168:46e05cb0
Other KBAs require you to run the setup_slot -init command to clear Slic signature failures. I found that the following process resolved my issue, but you may end up requiring to go through the setup_slot -init process. Examine the /nas/server/slot_x/start file entry and examine the "uniqueid validate=" line. Issue the following command to determine what the uniqueid entry should be: [nasadmin@ xxxxx ~]$ /nas/sbin/t2tty -C 3 "uniqueid" 1492624816: KERNEL: 6: WWN Seed (at address ffd80210): 46e05cb0 1492624816: SYSTEM: 6: uniqueid: "50060168:46e05cb0" 1492624816: ADMIN: 6: Command succeeded: uniqueid Edit the /nas/server/slot_x/start file using VI Editor and add the correct value to the "uniqueid validate=" line. You may have to add leading text "uniqueid validate=" as well. [nasadmin@ xxxxx ~]$ cat /nas/server/slot_3/start -serial swapserial #verify_start flashupg post=upgrade bios=upgrade fwbd=upgrade logsys add output disk=root_log_3 bufsz=256 logsys add output event bufsz=2048 ap boot setid celerraid=APXXXXXXXXXXXXXXXX setinitiator cs_hostname=Celerra_ xxxxx cs_external_ip=10.241.183.190 uniqueid validate=50060168:46e05cb0 < --- Edit the last line in file. Examine the /nas/server/slot_x/device file entry and examine the "slicsignature validate" line. If this line or details are missing, continue to the next step. Examine the "/nasmcd/getreason -e" command output to determine the data mover Slic codes. [nasadmin@xxxxx~]$ /nasmcd/getreason -e 10 - slot_0 primary control station 5 - slot_2 contacted(Post Code = 0x61 ; Mid Code = 0x80 ; Blade Code = 0x2c ; Slic Code = 132613) 5 - slot_3 contacted(Post Code = 0x61 ; Mid Code = 0x80 ; Blade Code = 0x2c ; Slic Code = 132613) Edit the /nas/server/slot_x/device file using VI Editor and add the correct value to the "slicsignature validate=" line. You may have to add the leading text "slicsignature validate=" as well. [nasadmin@xxxxx ~]$ cat /nas/server/slot_3/device device isa isa-0 device pci pci-0 dskdumpconfig full slot=3 pciautoconfig el3config tier2-aui slicsignature validate=132613 < --- Edit the last line in file. Rerun the "nas_checkup" to verify the errors have been fixed. You can run "nas_checkup -rerun" to only check the previous failures or errors. Escalate this issue through your Service Provider if needed and provide the nas_checkup output in the escalation.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.