VxRM cluster upgrade pre-check to make sure cluster not having self-signed certificate when vLCM enabled.. This test depends on the target code being specified when VxVerify is run: Test Result Result code Result Interpretation Pass 0 vLCM is enabled, and cluster not having self-signed certificate. Warning 1 vLCM is enabled, but cluster having self-signed certificate. Failure 2 This test has no failure result. Critical 3 This test has no critical result. An example of the health-check output is shown below: #========================#======#=========#====================================================================#==============# | Hostname / Category |Status Dell_KB | Warnings or Failures, unless tests Passed ; Product S.N. | #========================#======#=========#====================================================================#==============# | VxRM | Warning 479066 | vlcm_cert: vLCM enabled with Self-Signed cert |
VxRM cluster upgrade may fail in various stages when the cluster having self-signed certificate with vLCM enabled.
Contact Dell Support and refer to articles https://www.dell.com/support/kbdoc/en-us/000202110/dell-vxrail-upgrade-failed-to-upload-bundle-when-vlcm-is-enabled-and-vxrail-manager-tls-certificate-is-not-signed-by-vmca or https://www.dell.com/support/kbdoc/en-us/000199795/dell-vxrail-vxrail-upgrade-error-failed-to-upload-bundle-trigger-set-customized-depot-meets-exception