The Data Protection Restore Client (DPRC) is missing VM FLR or App backups. The following error appears for FLR or app-consistent SQL backups if no supported backups fall within the time-range specified. Alternatively, some VM backups may be listed and some backups which are expected to be available are missing. Backups from the specified time range are found using NetWorker server command: mminfo -avot -q vmname=VM_NAME
The backup data exists on a non-Data Domain type device. For example, save sets only exist on Tape: mminfo -avot -q vmname=VM_NAME -r "savetime(20),ssid,cloneid,sumflags,clflags,volume,type" [root@nsr ~]# mminfo -avot -q vmname=rhel-client01.amer.lan -r "savetime(20),ssid,cloneid,sumflags,clflags,volume,type" date time ssid clone id fl clflg volume type 02/09/2026 16:48 3028964897 1770674048 cr IM0001L1 LTO Ultrium [root@nsr ~]# mminfo -avot -q vmname=win-sql01.amer.lan -r "savetime(20),ssid,cloneid,sumflags,clflags,volume,type" date time ssid clone id fl clflg volume type 02/09/2026 14:58 3129621585 1770668648 cr IM0001L1 LTO Ultrium The "type" column must list "Data Domain" and the save set must be recoverable (cr). Important consideration regarding non-Data Domain type backups: The NetWorker VMware Protection (NVP) vProxy solution cannot backup or restore directly from tape. Performing an image restore (New VM, Revert VM, Disk, Instant Access, and so forth) provides "resurrection restore" functionality. This process involves selecting a clone pool on a Data Domain device. The restore automatically clones the save set to the Data Domain. Once the clone completes, the nsrvproxy_recover process is performed against the Data Domain copy. The described "resurrection restore" process is only supported for imaged-based restores, it is not possible to perform a resurrection restore for FLR or MSVMAPPAGENT backups. For more information see the NetWorker VMware Integration Guide, available through: Support for NetWorker | Manuals & Documents Data Protection Restore Client (DPRC) Functionality: This is expected behavior. The DPRC only performs FLR, and MSVMAPPAGENT restores. Since these restore types do not perform "resurrection restore," the non-Data Domain type save sets are not displayed in DPRC. NOTE: The scenario outlined in this KB demonstrates when ALL of the VMs backups within the time-range were on tape devices. If there are valid Data Domain backups within the time-range, the DPRC displays the valid Data Domain type save sets and ignores the non-Data Domain type ones. No error is provided; however, it appears that save sets are missing from DPRC.
Clone the save sets from the non-Data Domain type device to a Data Domain clone pool. This process is detailed in the following article: NVP vProxy: How to manually clone a VM save set from a non-Data Domain device to a Data Domain clone device Example: [root@nsr ~]# mminfo -avot -q ssid=3129621585 volume type client date time size ssid fl lvl name IM0001L1 LTO Ultrium vcsa.amer.lan 02/09/2026 02:58:08 PM 104 GB 3129621585 cr full vm:503ea434-0331-8ed6-8b19-b9cd408cce7a:vcsa.amer.lan [root@nsr ~]# nsrclone -S 3129621585/1770668648 -b VMClonePool 180169:nsrclone: Step (1 of 16): NSRCLONE_INIT_PHASE_ONE: nsrclone has been started on host 'nsr.amer.lan', with command 'nsrclone -S 3129621585/1770668648 -b VMClonePool '. ... ... ... [CLONE SUCCESS SAVESETS] 3129621585/1770736684; 180187:nsrclone: Step (15 of 16): NSRCLONE_TERMINATE_PHASE_FOUR: The nsrclone verification did not detect failures. 02/10/26 10:26:09.561179 Cloned save set list: : 3129621585/1770668648 [root@nsr ~]# mminfo -avot -q ssid=3129621585 -r "savetime(20),vmname,ssid,cloneid,sumflags,clflags,volume,type" date time vm_name ssid clone id fl clflg volume type 02/09/2026 14:58 win-sql01.amer.lan 3129621585 1770668648 cr IM0001L1 LTO Ultrium 02/09/2026 14:58 win-sql01.amer.lan 3129621585 1770736684 cr VMClonePool.001 Data Domain The DD copy of the cloned save set is displayed in the DPRC. If the save set is expired (E), you must change the retention period of the save set so that it becomes recoverable: nsrmm -e "MM/DD/YYYY HH:mm:SS" -S SSID/CLONEID Example: nsrmm -e "02/09/2026 14:45:00" -S 2374063791/1770084015 Save set flags are explained in the following article: NetWorker: Understanding Save Set Flags
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.