This issue occurs when connectivity is lost for an extended period without a clean replication break.Directory replication shows:Error: AUTH failed: secret key already setReplication is not in an uninitialized state.(If replication displays State: uninitialized and Sync'ed-as-of time: -, this article does not apply.)Running reauthentication on the source system returns: **** This command can only be run on an already initialized replica to prepare for recovery.
If the connection between the source and destination Data Domain systems is lost for a long period, the replication secret keys may fall out of sync. Because the replication context was not manually broken, the systems remain in an initialized state but cannot continue replication, resulting in the authentication failure.
The reauthentication (reauth) step should be performed only on the destination DD. CTX Source Destination Connection Host and Port Enabled --- ------------------------------------------------- ------------------------------------------------------------ -------------------------------------------- ------- 1 dir://source.datadomain.com/backup/weekly dir://dest.datadomain.com/backup/weekly-repl source.datadomain.com* (default)* yes --- ------------------------------------------------- ------------------------------------------------------------ -------------------------------------------- ------- * Used for recovery only. Connect to the source and destination DD using the Command-Line Interface (CLI) Data domain: How To Connect to a Data Domain System for Administration.Disable the file system on the source and destination DD by running the following command: # filesys disable Run the following command to obtain the full path or context (CTX) number: # replication show config Disable the replication on both the source and destination DD: # replication disable Reauthorize the destination Data Domain. Note: Replication "reauth" should be performed only on the destination. # replication reauth <destination path> Example: #replication reauth dir://dest.datadomain.com/backup/weekly Or the context number can be used: # replication reauth rctx://1 Enable the file system on source and destination DD. # filesys enable Enable replication on the source and destination DD. # replication enable rctx://1 ⚠️Note: If replication was manually broken on either system, recovery is not possible through reauthentication. Replication must be broken on both the source and destination systems, then recreated and fully resynchronized. If your problem persists after performing the steps in this article, upload a support bundle (SUB) and create a service request with your contracted support provider.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.