Alert ID: 8a3ffed9-d08c-4883-b7a4-240f7c80cd16 State:NEW Severity:CRITICAL Type:ARRAY Category:Storage Group Symmetrix:00029xxxxxx Object:test_snap Created: Mon Jan 12 2026 19:05:02 GMT-0500 Acknowledged: N/A Description: Storage Group test_snap with policy :test_hourly_snapshot needs xx snapshots and currently has 0 snapshots; the red count value is xx. The current compliance check time is 2026-01-13T00:05:00.265, the last check was 2026-01-12T23:05 when its snapshot count was xx Error Code: N/A
Only array‑level alerts include event codes managed through the storevntd daemon_options . This alert originates from the Unisphere for PowerMax side, not the daemon, so it does not have an associated event code .
There is no dedicated Array Event ID for Snapshot Policy compliance , so this behaviour cannot be controlled through the storevntd daemon_options settings. Snapshot policy compliance checks are performed by Unisphere for PowerMax every hour, based on the warning_compliance and critical_compliance thresholds defined in the policy. Since the alert shows an error_code of N/A , this indicates that the alert is functioning as designed.