The following criteria must be met: Have a firmware compliance baseline associated to the Enterprise Server Update catalog version 26.01.05 released January 02, 2026. Figure 1: OpenManage Enterprise (OME) catalog management showing impacted catalog version, 26.01.05 Create a firmware compliance job that only includes components where reboot required is 'No' and includes the firmware component shown as 'Dell' in the compliance report. Figure 2: Firmware Compliance report filtered for components where reboot required is 'No' and the component 'Dell' selected. After the firmware compliance job is completed, OpenManage Enterprise triggers a sever restart even though all components are listed as not requiring one. Figure 3: Task execution details showing restart required. Messages:RunningVerifying if the device Service Tag is valid.The device Service Tag is valid.Starting communication with the device.Update allowed in target, System Lockdown status = DISABLEDChecking Remote LC Services availabilityRemote LC Services are ready nowAttempting to initiate/stage payload instance: DCIM:INSTALLED#802__Plugin.Integrated.1028-dc100Initiated Status check for Job ID : JID_677258775545Job state for JID_677258775545 is DOWNLOADINGJob state for JID_677258775545 is COMPLETEDInitiating host reboot action as one or more payload(s) marked as reboot required. Completed
The Dell Connectivity Client (DCC) installer plug-in was added to the enterprise server update catalog (January 02, 2025, version 26.01.05). OpenManage Enterprise does not support this firmware component type and causes an unexpected server restart. The DCC plug-in is identified in the firmware compliance report with a component name of 'Dell' and baseline version of '100.4.0.'
Dell Technologies will add support for this firmware component in OpenManage Enterprise version 4.6.0 releasing January 08, 2026. Also, the DCC plug-in is temporarily removed from the next release of the enterprise server update catalog, version 26.01.07. The new catalog will be available on January 08, 2026. There are plans to add the DCC plug-in back into the enterprise server update catalog tentatively for the May or June 2026 release. As a workaround, do not select the 'Dell' component from the firmware compliance report. No further remediation steps are required once the new catalog is available or OpenManage Enterprise (OME) is updated to version 4.6.0.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.