Alert message: All IO to the Device will be stopped, and data will be relocated to other Devices. Device Name: <Device Name>, Device ID: <Device ID>, Device path: <Device Path>, Device Slot: <Device Slot>, Node: <Node Name>, ID: <Node ID> Impact The system will be in a degraded state. PowerFlex will attempt to rebuild/replicate the data on the failed device.
PowerFlex will exclude a Storage Node device that has run into an error. The error may be the result of multiple scenarios, such as a hard failure of the device, a device that is responding too slowly, or an issue with the RAID controller.
Attempt to clear the device error via SCLI: scli --clear_device_error --storage_node_name <Storage Node Name> --device_id <Device ID> If the device error cannot be cleared via SCLI, it may be necessary to replace the device. Verify the Device Group is in a Protected state before attempting to remove and replace the faulty device: scli --query_device_group --device_group_name <Device Group Name> --protection_domain_name <PD Name> | grep -i state Capacity Health State: Protected Impacted Versions PowerFlex 5.x