Shared PERC, BackPlane (BP), and hard disk drives (hard drive) are not seen in the Chassis Management Controller (CMC) Graphical User Interface (UI).The shared PERC LED is off, and the CMC log is not detecting the Shared PERC.
When a VRTX system configured with a single Shared PERC controller fails or the slot becomes faulty; communication to the BP and hard drive will be lost.The reason the Chassis UI is unable to see the hard drive and the BP is that the BP communicates directly with the shared PERC using the SAS ports on the MB, and if the shared PERC or the slot is not functioning, then the whole chain will not be seen.
Steps to try to troubleshoot VRTX with a single shared PERC configuration: Check the LED on shared PERC and main board and compare its activity in the owner's manual on page 97. If the issue persists and there are two CMCs then do a failover, but if there is one, then reset it (UI, CLI)If the issue still persists, contact Dell Technical Support for further troubleshooting.