New protection or change to disk layout for existing protection The CSV events shows: VMAX_000002,AS-Server,VMAX operation failed. Error: Not able to find SRDF group information for the source volume 001AF in array 000xxxxxxxxx GENL_000044,AS-Server,The following application items are on non-configured storage system or on an unsupported storage configuration: [DBNAME]. Register the required storage system in AppSync and/or verify that the underlying storage configuration is supported by AppSync. Also, verify if the storage preference set in the Service Plan is supported by the underlying array. SPP_000037,AS-Server,Cannot determine the storage type where application DBNAME resides. Verify if the application is located on a supported EMC storage that has been added to AppSync.
One of the Source Logical Unit Numbers (LUN) is not on a supported array and the SRDF error is erroneous.
Identify the LUN that is not on the Supported array and ensure it resides on a supported array.