ISSU to NX-OS 8.4.1 ISSUE: ISSU upgrade to 8.4(1) on MDS 9710 results with ISL reporting the following from the rest of the fabric Error = Illegal state transition and segmented Symptom: Failure communicating between switches for applications FSPF, CFS, FCNS, and FCS Examples: FSPF: %FSPF-3-FC2_PROC_ERR: %$VSAN 1%$ Error in processing LSA packet on interface port-channel xx, Error = Illegal state transition CFS example: show cfs internal notification log name device-alias` Sun Dec 8 18:46:58 2019: Remote app cap change for 20:00:00:05:73:d9:35:60 Sun Dec 8 18:46:58 2019: Peer add 20:00:00:05:73:d9:35:60 vsan 102, domain 48 Sun Dec 8 18:47:31 2019: Remote app cap change for 20:00:00:de:fb:bd:ba:c0 Sun Dec 8 18:47:31 2019: Peer add 20:00:00:de:fb:bd:ba:c0 vsan 102, domain 50 Sun Dec 8 18:47:37 2019: Peer gone 20:00:00:05:9b:2c:1b:f8 vsan 102, domain 44 Sun Dec 8 18:47:39 2019: Peer gone 20:00:00:3a:9c:02:d1:10 vsan 102, domain 60 Sun Dec 8 18:47:39 2019: Peer gone 20:00:00:de:fb:10:91:a0 vsan 102, domain 58 Sun Dec 8 18:47:39 2019: Peer gone 20:00:00:2a:6a:9e:14:48 vsan 102, domain 56 Sun Dec 8 18:47:39 2019: Peer gone 20:00:00:05:9b:2c:1b:a8 vsan 102, domain 46 In the logs after upgrade: 2019 Dec 8 18:57:40 E11NFCS02 %SYSMGR-SLOT4-5-LC_UPGRADE_START: Starting linecard upgrade 2019 Dec 8 18:57:44 E11NFCS02 %SYSMGR-SLOT4-5-LC_UPGRADE_REBOOT: Non-disruptively rebooting linecard as a part of upgrade 2019 Dec 8 18:58:41 E11NFCS02 %FSPF-3-FC2_PROC_ERR: %$VSAN 102%$ Error in processing LSA packet on interface port-channel22, Error = Illegal state transition *** 2019 Dec 8 18:58:59 E11NFCS02 %SYSMGR-SLOT4-4-READCONF_STARTED: Configuration update started (PID 1118). 2019 Dec 8 18:59:00 E11NFCS02 %SYSMGR-SLOT4-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1119). .. Continuous Port channel errors as below.... 2019 Dec 9 01:22:42 E11NFCS02 %FSPF-3-FC2_PROC_ERR: %$VSAN 102%$ Error in processing LSA packet on interface port-channel12, Error = Illegal state transition 2019 Dec 9 01:36:27 E11NFCS02 %FSPF-3-FC2_PROC_ERR: %$VSAN 102%$ Error in processing LSA packet on interface port-channel12, Error = Illegal state transition 2019 Dec 9 01:46:09 E11NFCS02 %FSPF-3-FC2_PROC_ERR: %$VSAN 102%$ Error in processing LSA packet on interface port-channel12, Error = Illegal state transition 2019 Dec 9 01:55:11 E11NFCS02 %FSPF-3-FC2_PROC_ERR: %$VSAN 102%$ Error in processing LSA packet on interface port-channel6, Error = Illegal state transition 2019 Dec 9 02:07:27 E11NFCS02 %FSPF-3-FC2_PROC_ERR: %$VSAN 102%$ Error in processing LSA packet on interface port-channel8, Error = Illegal state transition 2019 Dec 9 02:19:28 E11NFCS02 %FSPF-3-FC2_PROC_ERR: %$VSAN 102%$ Error in processing LSA packet on interface port-channel12, Error = Illegal state transition Could be any application where CFS is used for distribution.
Failure of FC2 frames between the switches causing segmentation.
Workaround: Do a system switchover to recover the cfs function. Switchover would recover the fabric segmentation.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.