when VSH run the command show inventory we can see a signal 11 issue on the process.
We can see the below logs: %VSHD-2-VSHD_SYSLOG_EOL_ERR: EOL function pfm_cli_show_inventory from library libpfm.so exited due to Signal 11 %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID xxxx with message vsh.bin(non-sysmgr) crashed, core will be saved . One or more vsh.bin core files will be generated as a result. See below: `show cores` VDC Module Instance Process-name PID Date(Year-Month-Day Time) --- ------ -------- --------------- -------- ------------------------- 1 27 1 vsh.bin 26604 2025-03-13 22:57:35 1 27 1 vsh.bin 10085 2025-03-20 12:04:50 1 27 1 vsh.bin 6516 2025-03-20 20:47:54
originally seen with Nexus9000 C9364C-GX version 10.4(5) running "show inventory all"
Use `show interface transceiver details` instead of `show inventory all` to display optics details