- Ethernet interfaces will be kept down when using front ports as FEX NIF on N9K-C93180YC-FX3 (FEX mode) connected to any front port on parent Nexus switch.
- Using front ports as FEX NIF on N9K-C93180YC-FX3 (FEX mode) connected to any front port on parent Nexus switch is not supported. An example would be: N9K-C93180YC-FX3 (FEX mode) Eth1/1 Eth1/1 N9K-C93180YC-FX3 (NX-OS 10.2.5)
- Use only uplinks on N9K-C93180YC-FX3 (FEX mode) towards parent Nexus switch (uplinks). - If you want to use the front ports on the parent Nexus switch, you can use breakout cable. - Currently, documentation missing the following statement: "N9K-FX3 in FEX mode support a breakout cable only from FEX NIF ports (Eth1/49-54) to parent switch FRONT ports". - This statement will be added to Additional Notes section in Nexus 9000 Series Switch FEX Support website: https://www.cisco.com/c/dam/en/us/td/docs/Website/datacenter/fexmatrix/fexmatrix.html
Lab test: ++ N9K-FX3-1 [ 4 x 10G ] Breakout [40GB] N9K-FX3-2 -------------------------------------------------------------------------------- Ethernet VLAN Type Mode Status Reason Speed Port Interface Ch # -------------------------------------------------------------------------------- Eth1/5 1 eth fabric up none 10G(D) 1 Eth1/6 1 eth fabric up none 10G(D) 1 Eth1/7 1 eth fabric up none 10G(D) 1 Eth1/8 1 eth fabric up none 10G(D) 1 FEX: 101 Description: FEX0101 state: Online FEX version: 10.2(6) [Switch version: 10.2(6)] Extender Model: N9K-C93180YC-FX3, Extender Serial: FLM27160T0C Part No: 73-102931-02 pinning-mode: static Max-links: 1 Fabric port for control traffic: Eth1/7 FCoE Admin: false FCoE Oper: true FCoE FEX AA Configured: false Fabric interface state: Po1 - Interface Up. State: Active Eth1/5 - Interface Up. State: Active Eth1/6 - Interface Up. State: Active Eth1/7 - Interface Up. State: Active Eth1/8 - Interface Up. State: Active ++ N9K-FX3-1 [ 4 x 25G ] Breakout [100GB] N9K-FX3-2 -------------------------------------------------------------------------------- Ethernet VLAN Type Mode Status Reason Speed Port Interface Ch # -------------------------------------------------------------------------------- Eth1/9 1 eth fabric up none 25G(D) 1 Eth1/10 1 eth fabric up none 25G(D) 1 Eth1/11 1 eth fabric up none 25G(D) 1 Eth1/12 1 eth fabric up none 25G(D) 1 FEX: 101 Description: FEX0101 state: Online FEX version: 10.2(6) [Switch version: 10.2(6)] Extender Model: N9K-C93180YC-FX3, Extender Serial: FLM27160T0C Part No: 73-102931-02 pinning-mode: static Max-links: 1 Fabric port for control traffic: Eth1/12 FCoE Admin: false FCoE Oper: true FCoE FEX AA Configured: false Fabric interface state: Po1 - Interface Up. State: Active Eth1/9 - Interface Up. State: Active Eth1/10 - Interface Up. State: Active Eth1/11 - Interface Up. State: Active Eth1/12 - Interface Up. State: Active
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.