C9800-L HA LED ligths on green color however HA is disabled on configuration. ------------------ show redundancy states ------------------ Load for five secs: 1%/0%; one minute: 1%; five minutes: 2% Time source is NTP, 19:08:36.819 JST Sat Nov 25 2023 my state = 13 -ACTIVE peer state = 1 -DISABLED Mode = Simplex Unit = Primary Unit ID = 1 Redundancy Mode (Operational) = Non-redundant Redundancy Mode (Configured) = sso Redundancy State = Non Redundant Maintenance Mode = Disabled Manual Swact = disabled (system is simplex (no peer unit)) Communications = Down Reason: Simplex mode Cisco Catalyst 9800-L Wireless Controller Hardware Installation Guide shows that HA LED on is for HA active as follows: Table 5. High Availability LED Indicators Off: HA disabled On: HA active Slow: Blink HA Hot Standby https://www.cisco.com/c/en/us/td/docs/wireless/controller/9800/9800-L/installation-guide/b-wlc-ig-9800-L/overview.html
Hardware: C9800-L Software: various versions. At least for 17.3.5b, 17.6.5, 17.9.4, and 17.12.2. HA is disabled on the configuration.
N/A
N/A