Symptom
Unicast traffic received on 9600X-SUP-2 Border from upstream devices is not sent out towards SDA fabric.
Conditions
On 9600X-SUP-2 Border error objects are seen for endpoint prefixes and FED next-hop is incorrectly programmed.
9600-B1R#show platform software object-manager f0 statistics
------------------ show platform software object-manager F0 statistics ------------------
Forwarding Manager Asynchronous Object Manager Statistics
Object update: Pending-issue: 0, Pending-acknowledgement: 0
Batch begin: Pending-issue: 0, Pending-acknowledgement: 0
Batch end: Pending-issue: 0, Pending-acknowledgement: 0
Command: Pending-acknowledgement: 0
Total-objects: 5339
Stale-objects: 0
Resolve-objects: 0
Childless-delete-objects: 0
Backplane-objects: 0
Error-objects: 301 <<<<<
Number of bundles: 0
Paused-types: 0
9600-B1R#$rm software object-manager f0 error | i 10.12.171.102
Description: PREFIX 10.12.171.102/32 (Table id 2)
9600-B1R#$e fed active ip route vrf CORP_VN 10.12.171.102/32
Load for five secs: 4%/0%; one minute: 1%; five minutes: 1%
No time source, *17:08:52.361 UTC Mon Jul 24 2023
------------------ show platform software fed active ip route vrf CORP_VN 10.12.171.102/32 ------------------
IPV4ROUTE_ID:id:0x556f522cde18 nobj:(NHADJ_DROP,0) 10.12.171.102/32 tblid:2 DA:0 <<<<<<<<<<<<<<< NHADJ_DROP
NPD: lspa_rec:0 api_type:3
SDK: is_host:0 l3_dest:0x7f0390d1cd00 l3_dest:la_next_hop
Fed Traces show error
{fed_F0-0}{1}: [fed3_l3u_npd] [29895:12730]: (debug): asic:0 FED3: lisp create vxlan next hop seq:0x206 entered action 1
{fed_F0-0}{1}: [fed3_l3u_npd] [29895:12730]: (ERR): asic:0 FED3: lisp create vxlan next hop seq:0x206 vxlan tunnel port get failed
Workaround
No workaround is available.