Switches suddenly go down and unable to fully boot. From console logs we see the following: Jun 20 12:11:29.139: %PMAN-3-PROCHOLDDOWN: R0/0: The process cmand has been helddown (rc 134) Jun 20 12:11:29.214: %PMAN-0-PROCFAILCRIT: R0/0: pvp: A critical process cmand has failed (rc 134) Jun 20 12:11:29.257: %PMAN-3-RELOAD_RP: R0/0: pvp: Reloading: Swie reloaded Chassis 0 reloading, reason - Non participant detected Jun 20 12:11:29.949: %PMAN-5-EXITACTION: F0/0: pvp: Process manager is exiting: reload fp action requested Jun 20 12:11:31.345: %PMAN-5-ETACTION: R0/0: pvp: Process manager is exiting: Critical process cmand fault on rp_0_0 (rc=134) <<<<<<<<<<<<<< Jun 20 12:11:33.762: %PMAN-3-PROCESS_NOTIFICATION: R0/0: pvp: System report /crashinfo/RP_0-system-report_local_20220620-121131-Universal.tar.gz (size: 12196 KB) generated Additional it can be seen in the internal logs before reboot: [errmsg] [xxxxx]: UUID: 0, ra: 0, TID: 0 (ALERT): (1): %CMAN_NYQ-1-CMAN_INIT_FAIL: CMAN: SUDI support initialization failed [cmand] [xxxxx]: UUID: 0, ra: 0, TID: 0 (FATAL): SUDI support init failed
No specific conditions known at the moment. TAC should be contacted to confirm if we are hitting this issue.
IOS upgrade to recent version is recommended to trying the recovery.
At this point the trigger and conditions are still unknown. It is a non-common issue that might be considered one-time event. There are some conditions that even IOS upgrade could not recover the device, in those scenrarios replacement is required after TAC analysis is performed.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.