The following log messages are seen: 2022 Aug 30 09:24:56 CORE-A-MGMT-1GMT1 %$ VDC-1 %$ %SYSMGR-SLOT25-2-SERVICE_CRASHED: Service "xbar_client" (PID 24504) hasn't caught signal 6 (no core). 2022 Aug 30 10:34:58 CORE-A-MGMT-1GMT1 %$ VDC-1 %$ %SYSMGR-SLOT22-2-SERVICE_CRASHED: Service "xbar_client" (PID 403) hasn't caught signal 6 (no core). 2022 Aug 30 10:34:59 CORE-A-MGMT-1GMT1 %$ VDC-1 %$ %SYSMGR-SLOT22-2-HAP_FAILURE_SUP_RESET: Service "xbar_client" in vdc 1 has had a hap failure During the investigation, we noticed communication errors between the LineCards and Supervisor after the Service crashes: 2022 Aug 30 10:35:01 CORE-A-MGMT-1GMT1 %$ VDC-1 %$ %KERN-0-SYSTEM_MSG: [2983201.382416] EMON: module 22 is not responding on EOBC path. Reloading module. - kernel 2022 Aug 30 10:35:01 CORE-A-MGMT-1GMT1 %$ VDC-1 %$ %MODULE-2-MOD_DIAG_FAIL: Module 22 (Serial number: JAE25110E3A) reported failure due to EOBC heartbeat failure in device DEV_EOBC_MAC (device error 0xc0a1b137) 2022 Aug 30 10:35:21 CORE-A-MGMT-1GMT1 %$ VDC-1 %$ %MODULE-2-MOD_DIAG_FAIL: Module 22 (Serial number: JAE25110E3A) reported failure due to Service on linecard had a hap-reset in device DEV_SYSMGR (device error 0x49)
This condition was identified on a N9K-C9508m running NX-OS nxos64-msll.10.2.3.F.bin. Also, it was identified multiple core file from the same service in different Fabric modules: `show cores` VDC Module Instance Process-name PID Date(Year-Month-Day Time) --- ------ -------- --------------- -------- ------------------------- 1 21 1 xbar_client 15520 2022-08-26 17:54:38 1 24 1 xbar_client 15512 2022-08-26 17:56:49 1 25 1 xbar_client 15512 2022-08-26 18:38:43 1 22 1 xbar_client 15513 2022-08-26 18:39:17 1 23 1 xbar_client 15521 2022-08-26 18:39:35 1 26 1 xbar_client 15515 2022-08-26 18:41:03 1 23 1 xbar_client 15510 2022-08-26 21:24:38 1 23 1 xbar_client 15508 2022-08-27 04:20:01 1 21 1 xbar_client 7564 2022-08-28 17:57:24 1 26 1 xbar_client 9063 2022-08-28 18:28:28 1 23 1 xbar_client 27991 2022-08-28 18:48:44 1 22 1 xbar_client 8946 2022-08-28 18:50:01 1 25 1 xbar_client 8974 2022-08-28 19:02:57 1 24 1 xbar_client 7655 2022-08-28 19:04:56 1 25 1 xbar_client 15511 2022-08-29 00:03:36 1 24 1 xbar_client 15510 2022-08-29 00:20:32 1 21 1 xbar_client 31362 2022-08-30 08:43:24 1 25 1 xbar_client 24504 2022-08-30 09:27:48 1 22 1 xbar_client 403 2022-08-30 10:35:21 1 23 1 xbar_client 1743 2022-08-30 10:57:17 `show module` Mod Ports Module-Type Model Status --- ----- ------------------------------------- --------------------- --------- snip... 21 0 Fabric Module N9K-C9508-FM-R2 ok 22 0 Fabric Module N9K-C9508-FM-R2 ok 23 0 Fabric Module N9K-C9508-FM-R2 ok 24 0 Fabric Module N9K-C9508-FM-R2 ok 25 0 Fabric Module N9K-C9508-FM-R2 ok 26 0 Fabric Module N9K-C9508-FM-R2 ok
A full reload of the system has been performed. No xbar_client has seen since then.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.