spwifi-glad-13#upgrade rom-monitor filename bootflash:qwlc-rommon.177-3r.pkg chassis active r0 spwifi-glad-13#reload C9800-40-K9 platform with 33554432 Kbytes of main memory Capsule Update Failed: Capsule image not found File size is 0x000015a4 Located packages.conf
seen only on few gladius(9800-40) and unable to upgrade rommon version.
Contact Cisco technical support, for assistance on recovery
spwifi-glad-13#upgrade rom-monitor filename bootflash:qwlc-rommon.177-3r.pkg chassis active r0 Verifying the code signature of the ROMMON package... Chassis model C9800-40-K9 has a single rom-monitor. Upgrade rom-monitor Target copying rom-monitor image file Secure update of the ROMMON image will occur after a reload. 131072+0 records in 131072+0 records out 131072 bytes (131 kB, 128 KiB) copied, 0.851432 s, 154 kB/s Copying ROMMON environment 131072+0 records in 131072+0 records out 131072 bytes (131 kB, 128 KiB) copied, 0.729181 s, 180 kB/s 131072+0 records in 131072+0 records out 131072 bytes (131 kB, 128 KiB) copied, 0.72668 s, 180 kB/s ROMMON upgrade complete. To make the new ROMMON permanent, you must restart the RP. spwifi-glad-13#reload System configuration has been modified. Save? [yes/no]: no Reload command is being issued on Active unit, this will reload the whole stack Proceed with reload? [confirm] Aug 9 20:20:24.809: %SYS-5-RELOAD: Reload requested by wnbu on console. Reload Reason: Reload Command. Chassis 1 reloading, reason - Reload command Aug 9 14:20:30.889: %PMAN-5-EXITACTION: F0/0: pvp: Process manager is exiting: Aug 9 14:20:30.909: %PMAN-5-EXITACTION: C0/0: pvp: Process manager is exiting: Au044: %PMAN-5-EXITACTION: R0/0: pvp: Process manager is exiting: process exit with reload chassis code Initializing Hardware ... System integrity status: 90170200 12030107 System Bootstrap, Version 16.10(2r), RELEASE SOFTWARE Copyright (c) 1994-2018 by cisco Systems, Inc. Current image running: Boot ROM0 Last reset cause: LocalSoft C9800-40-K9 platform with 33554432 Kbytes of main memory Successfully initiated a secure capsule update. The system will be reset multiple times for completing the capsule update. Please wait till you get the prompt. Initializing Hardware ... System integrity status: 90170200 12030107 System Bootstrap, Version 16.10(2r), RELEASE SOFTWARE Copyright (c) 1994-2018 by cisco Systems, Inc. Current image running: Boot ROM0 Last reset cause: LocalSoft C9800-40-K9 platform with 33554432 Kbytes of main memory Capsule Update Failed: Capsule image not found File size is 0x000015a4 Located packages.conf Image size 5540 inode num 35, bks cnt 2 blk size 8*512 # File size is 0x022387c0 Located C9800-rpboot.17.09.01.SPA.pkg Image size 35882944 inode num 679940, bks cnt 8761 blk size 8*512 ############################################################################################################################################################################################################################################################################################################################################################## Boot image size = 35882944 (0x22387c0) bytes ROM:RSA Self Test Passed ROM:Sha512 Self Test Passed Package header rev 3 structure detected Calculating SHA-1 hash...done validate_package_cs: SHA-1 hash: calculated db4b763d:7e04d221:2b7812cb:cdba8660:04f05658 expected db4b763d:7e04d221:2b7812cb:cdba8660:04f05658 Validating main package signatures RSA Signed RELEASE Image Signature Verification Successful. Image validated Aug 9 20:23:13.143: %BOOT-3-BOOTTIME_SMU_MISSING_DETECTED: R0/0: install_engine: SMU file /bootflash/C9800-universalk9_wlc.2022-06-28_03.08_smudev.80952.CSCxxxxxxx.SSA.smu.bin missing and system impact will be unknown Waiting for remote chassis to join ####################################################################################################################### Chassis number is 1 Restricted Rights Legend
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.