OPERATIONAL DEFECT DATABASE
...

...
If following syslog is seen then customer might be hitting this issue. Below syslog is very high-level. To confirm whether asr9k is hitting this issue, please check the steps mentioned in "Conditions" section. In 4.2.x ========== RP/0/RSP0/CPU0:Nov 21 15:00:17.099 UTC: pfm_node_rp[358]: %PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED : Set|online_diag_rsp[233591]|System Punt/Fabric/data Path Test(0x2000004)|failure threshold is 3, (slot, NP) failed: (0/1/CPU0, 0) (0/1/CPU0, 1) (0/1/CPU0, 2) (0/1/CPU0, 3) (0/1/CPU0, 4) (0/1/CPU0, 5) (0/1/CPU0, 6) 4.3.2 and greater: ========================== FABMGR[222]: %PLATFORM-FABMGR-5-FABRIC_TRANSIENT_FAULT : Fabric backplane crossbar link underwent link retraining to recover from a transient error: Physical slot 1
Issue is due to fabric retrain in LC ==> RSP direction (RX to RSP). Collect ltraces from RSP's and LC to confirm whether there was fabric-retrain. All 3 lines of output should match. Example log: RP/0/RSP0/CPU0:asr9k#show controllers fabric ltrace crossbar location 0/RSP0/CPU0 | in retrain [or 0/RSP1/CPU0] Nov 21 14:57:17.494 crossbar 0/RSP0/CPU0 t1 init xbar_trigger_link_retrain: destslot:4 fmlgrp:3 rc:0 Nov 21 14:57:17.494 crossbar 0/RSP0/CPU0 t1 detail xbar_pfm_alarm_callback: xbar_trigger_link_retrain(): (4,1,0) initiated Nov 21 14:57:17.499 crossbar 0/RSP0/CPU0 t1 detail xbar_fmlc_handle_link_retrain: rcvd link_retrain for (4,1,0),(1,1,0),0 <=== Indicates RSP is receiving fabric retrain from LC in slot 1. See below for slot mapping info RP/0/RSP0/CPU0:asr9k# slot matching: [In the above output slot 1 is logical. Below data shows how to match logical-to-physical slot mapping ============== Chassis Type : 9010 Physical-Slot Logical-slot ========================== 0 0 1 1 2 2 3 3 4 RSP 5 RSP 6 4 7 5 8 6 9 7
No workaround. This is not a hardware issue. No need for RMA.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.