OPERATIONAL DEFECT DATABASE
...

...
After upgrade to fix related defect CSCvy10601, some Catalyst 9200L switches continue to report fan failure messages, but reported faulty fan can be observed still operational / spinning. The messages displayed constantly %PLATFORM_THERMAL-6-FRU_FAN_RECOVERY: Switch 1: System fan # recovered to normal status %PLATFORM_THERMAL-1-FRU_FAN_FAILURE: Switch 1: System fan # failed show environment fan Switch FAN Speed State --------------------------------------------------- 1 1 5160 OK 1 2 0 NOT PRESENT or FAULTY * Physically the FAN # works although it displayed the error messages * The temperature of the device is in normal parameters
* Must be running a fixed version for CSCvy10601 * FAN # reports a failure * FAN # shows a message that it recovered * Reload doesn't help, message comes back after a while
- Reload (Fix the issue temporarily) If reload does not clear condition then power cycle. The workaround is temporary.
- The FANs show a failure message and that the FAN recovers by itself, FAN # works although this message comes out continuously - CSCvy10601 contained adjustments to fan monitoring parameters. Some devices continue to report fan failure despite fan functioning normally. Contact Cisco TAC if you are running a fixed version for CSCvy10601 and you suspect this issue. - The defect CSCwc77585 addresses the issue partially. Complete resolution of the issue is provided by the fix of the defect - CSCwd56540. Fix is available in the CCO version of 17.3.7, 17.6.5, 17.9.3, 17.11.1 and later releases.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.