Symptom
9200L had BL:17.9.1r [FC2], MVP-DEVELOPMENT SOFTWARE
Loaded POLARIS_DEV_LATEST_20220602_224053 image on switch , auto BL upgrade triggered and BL upgraded to 17.9.1r [FC4] during the image bootup. once BL upgrade , switch is trying to boot up with BL 17.9.1r [FC4] and IOS POLARIS_DEV_LATEST_20220602_224053
Here Mainboard hardware authentication failed & Abort init issue seen. switch is not coming up.
Initializing Hardware...
System Bootstrap, Version 17.9.1r [FC2], MVP-DEVELOPMENT SOFTWARE
Compiled Mon 03/14/2022 17:51:01 by chinmoha
Copyright (c) 2022 by Cisco Systems, Inc.
Current ROMMON image : Primary
C9200L-24T-4G platform with 2097152 Kbytes of main memory
boot: attempting to boot from [flash:packages.conf]
boot: reading file packages.conf
##############
*Jun 03 20:07:31.794: %IOSXEBOOT-4-BOOTLOADER_UPGRADE: (rp/0): ### Fri Jun 3 20:07:31 Universal 2022 PLEASE DO NOT POWER CYCLE ### BOOT LOADER UPGRADING
*Jun 03 20:07:45.617: %IOSXEBOOT-4-BOOTLOADER_UPGRADE: (rp/0): Fri Jun 3 20:07:45 Universal 2022 Bootloader upgrade successful
*Jun 03 20:07:45.630: %IOSXEBOOT-4-BOOTLOADER_UPGRADE: (rp/0): Reloading to enable the New BOOTLOADER and MCU
Jun 3 20:07:49.279: %PMAN-5-EXITACTION: C0/0: pvp: Process manager is exiting:
Jun 3 20:07:49.893: %PMAN-5-EXITACTION: F0/0: pvp: Process manager is exiting:
watchdog: watchdog0: watchdog did not stop!
watchdog: watchdog0: watchdog did not stop!
reboot: Restarting system
Initializing Hardware...
System Bootstrap, Version 17.9.1r [FC4], RELEASE SOFTWARE (P)
Compiled Wed 03/23/2022 08:59:50 by rel
Current ROMMON image : Primary
C9200L-24T-4G platform with 2097152 Kbytes of main memory
boot: attempting to boot from [flash:packages.conf]
boot: reading file packages.conf
##############
Mainboard hardware authentication failed, Abort init ...