C9400-LC-48S or C9400-LC-24S line card will reload after inserting an SFP.
This has been seen with "GLC-LH-SM", "GLC-LH-SMD", "GLC-SX-MM", and "GLC-SX-MMD" SFP's. Running IOS-XE version 16.12.6 C9400-LC-24S and C9400-LC-48S are both vulnerable to the issue.
This issue has not been seen in other 16.12.X and 17.X versions. Upgrade or downgrade from 16.12.6 will avoid this issue.
PSIRT Evaluation: The Cisco PSIRT has evaluated this issue and determined it does not meet the criteria for PSIRT ownership or involvement. This issue will be addressed via normal resolution channels. If you believe that there is new information that would cause a change in the severity of this issue, please contact psirt@cisco.com for another evaluation. Additional information on Cisco's security vulnerability policy can be found at the following URL: http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html