Observed when Nexus 9300 series device was upgraded from 9.3.4 to 9.3.8, you will observe "type-2 inconsistency - QoSMgr Qos configuration incompatible " error when you issue "Show VPC Brief"
1.The symptom is observed when we upgrade NXOS from 9.3.4 to 9.3.8. This symptom was observed after the upgrade. 2. Non disruptive ISSU 7.0(3)I7(8) --> 9.3(9) on N9K-C93108TC-EX
2 Worrkarounds: ============ 1. Reload. 2. This is a timing issue and is resolves on it's own after some time. Roughly less than a day or more.
N9K# sh vpc Legend: (*) - local vPC is down, forwarding via vPC peer-link vPC domain id : 1 Peer status : peer adjacency formed ok vPC keep-alive status : peer is alive Configuration consistency status : success Per-vlan consistency status : success Type-2 consistency status : failed >>> error Type-2 inconsistency reason : QoSMgr Qos configuration incompatible.>>> error vPC role : secondary Number of vPCs configured : 16 Peer Gateway : Enabled Dual-active excluded VLANs : - Graceful Consistency Check : Enabled Auto-recovery status : Disabled Delay-restore status : Timer is off.(timeout = 400s) Delay-restore SVI status : Timer is off.(timeout = 10s) Operational Layer3 Peer-router : Enabled Virtual-peerlink mode : Disabled