It will wait for about one minute and then reboot when I run below command. WLCXXX#show logging profile wireless start last 5 days **MM/DD 09:19:48.526: %STACKMGR-6-CHASSIS_ADDED: Chassis 2 R0/0: stack_mgr: Chassis 1 has been added to the stack. Logging display requested on *MM/DD/YYYY 09:19:52 (UTC) for Hostname: [WLCXXX], Model: [C9120AXI-H], Version: [17.05.01], SN: [XXXXXX], MD_SN: [XXXXXX] Displaying logs from the last 5 days, 0 hours, 0 minutes, 0 seconds executing cmd on chassis 2 ... [ OK ] Stopped target Timers. Stopping Tftpd-hpa Daemon... Stopping Cisco led service... Stopping DHCPv6 client... [ OK ] Stopped …… 5.0205HNDRC1a-1.0.38-163.162 CPU0 L1CD MMUI MMUA CODE ZBBS MAIN Boot Strap Register: 0x6fc7b NVRAM memcfg 0x60607 DDR3-1600 CL11 total 2048MB 4 8bits part[s] DDR test done successfully CFE Version: 5 Verifying MASTER U-Boot... Launching MASTER U-Boot version 0x0044 ... ____ _ / ___|(_) ___ ___ ___ | | | |/ __| / __|/ _ \ | |___ | |\__ \| (__| (_) | \____||_||___/ \___|\___/ _ _ ____ _ | | | | | __ ) ___ ___ | |_ | | | |___| _ \ / _ \ / _ \| __| | |_| |___| |_) | (_) | (_) | |_ \___/ |____/ \___/ \___/ \__| U-Boot 2017.09 (Feb 05 2021 - 11:50:07 -0800) Broadcom BCM49408
Running show logging CLI with a large time window e.g here 5 days were used.
Select a smaller time window for 'show logging' CLI using 'start last' options.
When a large time window is set for "show logging CLI" using "start last" keywords, the box runs out of memory and reloads.