Symptom
It will wait for about one minute and then reboot when I run below command.
WLCXXX#show logging profile wireless start last 5 days
**MM/DD 09:19:48.526: %STACKMGR-6-CHASSIS_ADDED: Chassis 2 R0/0: stack_mgr: Chassis 1 has been added to the stack.
Logging display requested on *MM/DD/YYYY 09:19:52 (UTC) for Hostname: [WLCXXX], Model: [C9120AXI-H], Version: [17.05.01], SN: [XXXXXX], MD_SN: [XXXXXX]
Displaying logs from the last 5 days, 0 hours, 0 minutes, 0 seconds
executing cmd on chassis 2 ...
[ OK ] Stopped target Timers.
Stopping Tftpd-hpa Daemon...
Stopping Cisco led service...
Stopping DHCPv6 client...
[ OK ] Stopped
……
5.0205HNDRC1a-1.0.38-163.162
CPU0
L1CD
MMUI
MMUA
CODE
ZBBS
MAIN
Boot Strap Register: 0x6fc7b
NVRAM memcfg 0x60607
DDR3-1600 CL11 total 2048MB 4 8bits part[s]
DDR test done successfully
CFE Version: 5
Verifying MASTER U-Boot...
Launching MASTER U-Boot version 0x0044 ...
____ _
/ ___|(_) ___ ___ ___
| | | |/ __| / __|/ _ \
| |___ | |\__ \| (__| (_) |
\____||_||___/ \___|\___/
_ _ ____ _
| | | | | __ ) ___ ___ | |_
| | | |___| _ \ / _ \ / _ \| __|
| |_| |___| |_) | (_) | (_) | |_
\___/ |____/ \___/ \___/ \__|
U-Boot 2017.09 (Feb 05 2021 - 11:50:07 -0800) Broadcom BCM49408
Conditions
Running show logging CLI with a large time window e.g here 5 days were used.
Workaround
Select a smaller time window for 'show logging' CLI using 'start last' options.
Further Problem Description
When a large time window is set for "show logging CLI" using "start last" keywords, the box runs out of memory and reloads.