cEdge C8300-1N1S-6T Flow control go down after reload the cEdge with manual speed "100" on the interface configuration in place.
cEdge C8300-1N1S-6T with manual speed on the interface
1 - Configure the interface for no negotiation auto will get the Flow-Control up. 2 - if auto negotiationis needed, configure it after the workaround point 1 is done. however you need to do this workaround after each reboot.
- Issue been reproduced on the lab as the following order: 1. When auto negotiation is on the Flow-Control is OFF 2. Config Speed manual to 100Mbps on the interface get the Flow-Control ON 3. Reboot the device. 4. Flow-Control goes Off <--- should not. 5. Revert back to auto negotiation. Flow-Control Still OFF 6. Config Speed 100Mbps on the interface get the Flow-Control Back up.