Loading...
Loading...
A vulnerability in the processing of SSH connections of Cisco Firepower Management Center (FMC) and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. This vulnerability is due to improper error handling when an SSH session fails to be established. An attacker could exploit this vulnerability by sending a high rate of crafted SSH connections to the instance. A successful exploit could allow the attacker to cause resource exhaustion, resulting in a reboot on the affected device. Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. This advisory is available at the following link: https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-dos-OwEunWJN
Please refer to the Security Advisory.
Please refer to the Security Advisory.
Please refer to the Security Advisory.
The Cisco PSIRT has assigned this bug the following CVSS version 3 score. The Base CVSS score as of the time of evaluation is 7.5: https://tools.cisco.com/security/center/cvssCalculator.x?vector=CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE ID CVE-2022-20854 has been assigned to document this issue. Additional information on Cisco's security vulnerability policy can be found at the following URL: https://tools.cisco.com/security/center/resources/security_vulnerability_policy.html
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise