After upgrading N7K to 8.4(3), 8.4(4), 8.2(6) or later, the load interval (I/O rates) are missing from the SVI show interface command output. This only happens to the SVI interfaces. Physical interfaces are not affected. When the switch is running a previous release to the ones mentioned above, the I/O rates are displayed in the command output: switch-vdc1# show module Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 1 12 10/40 Gbps Ethernet Module N7K-F312FQ-25 ok 5 0 Supervisor Module-2 N7K-SUP2E active * Mod Sw Hw --- --------------- ------ 1 8.4(2) 1.1 5 8.4(2) 1.1 switch-vdc1# sh int vlan 10 Vlan10 is down (VLAN/BD is down), line protocol is down, autostate enabled Hardware is EtherSVI, address is 8478.ac1f.c6c2 MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not supported ARP type: ARPA Last clearing of "show interface" counters never Load-Interval #1: 1 minute (60 seconds) 60 seconds input rate 0 bits/sec, 0 packets/sec <<< 60 seconds output rate 0 bits/sec, 0 packets/sec Load-Interval #2: 5 minute (300 seconds) input rate 0 bps, 0 pps; output rate 0 bps, 0 pps L3 Switched: input: 0 pkts, 0 bytes - output: 0 pkts, 0 bytes L3 in Switched: ucast: 0 pkts, 0 bytes - mcast: 0 pkts, 0 bytes L3 out Switched: ucast: 0 pkts, 0 bytes - mcast: 0 pkts, 0 bytes When the switch is running one of the releases mentioned above, the I/O rates are no longer displayed: switch# show module Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 1 12 10/40 Gbps Ethernet Module N7K-F312FQ-25 ok 5 0 Supervisor Module-2 N7K-SUP2E active * Mod Sw Hw --- --------------- ------ 1 8.4(3) 1.1 5 8.4(3) 1.1 switch-vdc1(config-if)# show int vlan 10 Vlan10 is up, line protocol is up, autostate enabled Hardware is EtherSVI, address is 8478.ac1f.c6c2 MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not supported ARP type: ARPA Last clearing of "show interface" counters never L3 Switched: <------------- load interval rates are missing input: 0 pkts, 0 bytes - output: 0 pkts, 0 bytes L3 in Switched: ucast: 0 pkts, 0 bytes - mcast: 0 pkts, 0 bytes L3 out Switched: ucast: 0 pkts, 0 bytes - mcast: 0 pkts, 0 bytes
N7K running either of the following releases: 8.2(6) 8.2(7) 8.2(7a) 8.4(3) 8.4(4)
There is no workaround for this.
These outputs for the SVI interface have been restored in 8.4(5).
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.