9300 shows these message repeatedly: Mar 2 00:14:29.515: %THERMAL-1-THERMAL_GREEN_THRESHOLD: Switch 1 R0/0: cmand: Hotspot temperature has exceeded GREEN threshold Mar 4 21:05:03.711: %THERMAL-1-THERMAL_GREEN_THRESHOLD: Switch 1 R0/0: cmand: Hotspot temperature has exceeded GREEN threshold Mar 6 16:51:46.745: %THERMAL-1-THERMAL_GREEN_THRESHOLD: Switch 1 R0/0: cmand: Hotspot temperature has exceeded GREEN threshold ----------------- show environment all ------------------ Switch FAN Speed State --------------------------------------------------- 1 1 14240 OK 1 2 14240 OK 1 3 14240 OK FAN PS-1 is OK FAN PS-2 is OK Switch 1: SYSTEM TEMPERATURE is OK Inlet Temperature Value: 37 Degree Celsius Temperature State: GREEN Yellow Threshold : 46 Degree Celsius Red Threshold : 56 Degree Celsius Outlet Temperature Value: 42 Degree Celsius Temperature State: GREEN Yellow Threshold : 105 Degree Celsius Red Threshold : 125 Degree Celsius Hotspot Temperature Value: 55 Degree Celsius Temperature State: GREEN Yellow Threshold : 105 Degree Celsius Red Threshold : 125 Degree Celsius SW PID Serial# Status Sys Pwr PoE Pwr Watts -- ------------------ ---------- --------------- ------- ------- ----- 1A PWR-C1-350WAC-P DCC2449B6DW OK Good n/a 350 1B PWR-C1-350WAC-P DCC2449B6WZ OK Good n/a 350 customer downgrade to 16.9.5, logs does not show up again
version 16.12.4
downgrade to 16.9.4
None