Deployment failure with Error Message "The Policy requires THREAT license ,but atleast one of the devices does not have a THREAT license" when no Threat License is enabled and add a different blank and custom SI URL or Network list. However, if you leave just the Global Whitelist and Blacklist for Network and/or URL error did not appear and deployment completed without errors. As per the Firepower Guide, Configure Security Intelligence requires to have a Threat License enabled https://www.cisco.com/c/en/us/td/docs/security/firepower/660/configuration/guide/fpmc-config-guide-v66/security_intelligence_blacklisting.html#ID-2192-00000098
Under the Security Intelligence settings of an Access Control Policy assigned to a sensor with no Threat License enabled, using custom SI Network and URL lists.
Deployment error should not appear if you leave in blank the Security Intelligence lists or add the Global lists.
This appears when you try to create a New Object Groups on FMC on Objects > Object Management > Distinguished Name > Object Groups > Add Distinguished Name Group This deployment error message should appear in any case, with any Security Intelligence list assigned if the Threat License is not enabled. And Error message should appear if any list is being added to the policy linked to the not licensed sensor.