HW: C9200-48P-E (NM module:C9200-NM-4X) SW: 16.12.03/ 16.12.3a / 16.12.4 Problem Description: Uplink module C9200-NM-4X is not detecting after soft reload. Customer see the issue on every reload and many C9200-48P-E switches have the same symptoms. This issue only occurs when perform warn restart (reload command) and when perform cold restart(hard reboot) the C9200-NM-4X detect normally. Uplink module is not shows in Show inventory: WTR-7FL2_SW06#show inventory NAME: "c92xx Stack", DESCR: "c92xx Stack" PID: C9200-48P , VID: V01 , SN: JAE23410R63 NAME: "Switch 1", DESCR: "C9200-48P" PID: C9200-48P , VID: V01 , SN: JAE23410R63 NAME: "Switch 1 - Power Supply A", DESCR: "Switch 1 - Power Supply A" PID: PWR-C6-1KWAC , VID: V01 , SN: DCI2329N72X NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B" PID: PWR-C6-1KWAC , VID: V01 , SN: DCI2348N4LW After around 10 minutes uplink module shows in : WTR-7FL2_SW06#show inventory NAME: "c92xx Stack", DESCR: "c92xx Stack" PID: C9200-48P , VID: V01 , SN: JAE23410R63 NAME: "Switch 1", DESCR: "C9200-48P" PID: C9200-48P , VID: V01 , SN: JAE23410R63 NAME: "Switch 1 - Power Supply A", DESCR: "Switch 1 - Power Supply A" PID: PWR-C6-1KWAC , VID: V01 , SN: DCI2329N72X NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B" PID: PWR-C6-1KWAC , VID: V01 , SN: DCI2348N4LW NAME: "Switch 1 FRU Uplink Module 1", DESCR: "4x10G Uplink Module" PID: C9200-NM-4X , VID: V01 , SN: JAD23300FWW NAME: "Te1/1/3", DESCR: "SFP-10GBase-SR" PID: SFP-10G-SR , VID: V03 , SN: AVD2020A31S NAME: "Te1/1/4", DESCR: "SFP-10GBase-SR" PID: SFP-10G-SR , VID: V03 , SN: AVD2001A384
1/ soft reload 2/ Issue only occurs while insert SFP module.
Issue got resolved after upgrading the IOS-XE version to 17.3.3
none
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.