DHCP Offers/Acks from a Cat3650/3850 or Cat9K configured as DHCP server can remove/corrupt certain DHCP options, if "netbios-node-type" (option 46) configuration is present on the DHCP pool. Sample of a problematic configuration: ip dhcp pool TEST network a.a.a.0 255.255.252.0 < Opt 1, len: 4B default-router a.a.a.1 < Opt 3, len: 4B netbios-name-server b.b.b.b < Opt 44, len: 4B netbios-node-type h-node < Opt 46, len: 1B domain-name test.cisco.com < Opt 15, len: 14B dns-server c.c.c.c < Opt 6, len: 4B A working DHCP Offer/Ack should have the following fields: Option: (1) Subnet Mask Length: 4 Subnet Mask: 255.255.252.0 Option: (3) Router Length: 4 Router: a.a.a.1 Option: (44) NetBIOS over TCP/IP Name Server Length: 4 NetBIOS over TCP/IP Name Server: b.b.b.b Option: (46) NetBIOS over TCP/IP Node Type Length: 1 NetBIOS over TCP/IP Node Type: H-node (8) Option: (15) Domain Name Length: 14 Domain Name: test.cisco.com Option: (6) Domain Name Server Length: 4 Domain Name Server: c.c.c.c Option: (255) End Option End: 255 Instead, we see options after Opt 46/Opt 6 are missing, and their data gets appended into the option above, respectively (Opt 44/Opt 15): Option: (1) Subnet Mask Length: 4 Subnet Mask: 255.255.252.0 Option: (3) Router Length: 4 Router: a.a.a.1 Option: (44) NetBIOS over TCP/IP Name Server Length: 5 < Opt 44 + 46 NetBIOS over TCP/IP Name Server: b.b.b.b [Expert Info (Error/Protocol): Option length isn't a multiple of 4] [Option length isn't a multiple of 4] [Severity level: Error] [Group: Protocol] Option: (15) Domain Name Length: 18 < Opt 15 + 6 Domain Name: test.cisco.com\002\002\002\002 Option: (255) End Option End: 255 Other options configured below the netbios options on the config can be affected by this issue, it is not just for the options presented on the example above.
Seen on Catalyst 3650/3850, and all Catalyst 9000 switches running 16.12.3a only. Not seen on IOS below or above 16.12.3a.
Remove NetBIOS Node-type option (46) configurations.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.