OPERATIONAL DEFECT DATABASE
...

...
- After register ASR920 to CSSM using SL, device is taking license 2portGE-4ports10GE instead of 10GEupgradelicense License Usage ============== ASR 920 2GE-4-10GE PORT LICENSE (2portGE-4ports10GE): Description: ASR 920 2GE-4-10GE PORT LICENSE Count: 1 Version: 1.0 Status: OUT OF COMPLIANCE Export status: NOT RESTRICTED License is going Our Of Compliance. Having one TenGig port up or four TengGig ports up is having the same issue.
ASR-920-4SZ-A running 16.12.1 with Smart License configured.
One possible workaround is - [1] - Remove smart licensing conf t no license smart enable - Request temp .lic license for 10GEupgradelicense - Install .lic file license install bootflash: - Verify that ASR is taking license 10GEupgradelicense router#sh lic feature Feature name Enforcement Evaluation Subscription Enabled RightToUse advancedmetroipaccess yes yes no no no metroipaccess yes yes no no no metroaccess no yes no no no 1588 yes yes no no no 10GEupgradelicense yes no no yes no << 2portGE-4ports10GE yes no no no no *For this step reload may be required. - Enable Smart Licensing back again and register device. conf t license smart enable end license smart register idtoken #token force Now CSSM should take the proper license License Usage ============== ASR 920 2-10G PORT LICENSE (10GEupgradelicense): Description: ASR 920 2-10G PORT LICENSE Count: 1 Version: 1.0 Status: AUTHORIZED Export status: NOT RESTRICTED [2] - Ask for a smart temp license - 2portGE-4ports10GE to be allocated in your Virtual Account.
NA
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.